Chart Recorders

Pressure Recorders

BACK to Chart Recorders Menu
Pressure Chart Recorder

Features

These reliable and accurte instruments are suitable for most applications where there is a requirement for low cost pressure recording.

Up to three pens can be fited with three pressure systems or combinations of pressure, temperature or flow sensing systems.

The case is suitable for surface or panel mounting or may be specified as portable or pipe mounting.

Pens

Fitted to the pen arms are disposable fibre tipped pens which are readily replaced without mess. Single pen recorders and the first pen of two and three pen recorders trace in red ink, the second pen in blue, the third in green.

Chart and chart drive

Charts are supplied normally with the minimum value of pressure at the centre, although other styles are available. Standard charts durations are one revolution every 24 hours or 7 days with special durations available on request. Chart drive may be electric, spring would or battery operated. A pen lift is fitted to ease chart changing.

Intrinsically safe applications

An all mechanical version is available for applications where no electrical supply is available or where an intinsically safe instrument is required. Chart drive for this version uses a mechanical sprint wound motor.

Control Options

Specification

Accuracy ±1% FSD.
Ambient Temperature -20oC to +50o.
Measuring Element Bourdon tube pressure capsule, as applicable.
Chart Drive Synchronous electric, mechanical spring wound or battery operated. 24 hour or 7 day. Other rotations on request.
Charts Disc 24mm (9·5 inches) diameter. Standard dividing 40, 50, 60, 70, or 80 inear divisions.
Inking System Disposable fibre tipped pen.
Single pen: red.
2 pen: red and blue.
3 pen: red, blue and green.
Case Glass filled polyester resin. Protected to IP55.
Window Acrylic.
Power Supply 200 to 250 volts, 50Hz (60Hz available).
100 to 120 volts, 50Hz (60Hz available).
Instruments without electrical control require no power supply provided that a mechanical sping wound chart drive is fitted. For battery operation 1·5v 'C' type cell.
Electrical Alarm and Control
Contact rating:
(When fitted)
Relay contact rating:
(When fitted)
Contact adjustment range:
0·1A at 250V A.C. (non inductive).
0·01A at 250V D.C. (non inductive).
10A at 250V 50Hz.
5A at 415V 50Hz.

2% to 100%
Connection
Standard

Portable

Receiver type:
input 3- 15 p.s.i. 0·2 - 1 bar
3/8" BSP Male, with nut and tail pipe suitable for 6·35mm (1/4") outside diameter tube.
3/8" BSP Male, with nut and tail pipe suitable for 6·35mm (1/4") outside diameter tube or 3/8" inside diameter tube.
1/4" BSP female.
Mounting Suitable for surface or panel mounting. (pipe mounting and portable options available).
Weight Single pen: 6·5Kg (14·25lb).
Two pen: 7Kg (15·5lb).
Three pen: 7·5Kg (16·75lb).
Portable single pen: 8·6Kg (19lb).
Pressure Chart Recorder Dimensions
Standard Range Sensing Element Type Material
0 - 10"WG
0 - 15"WG
0 - 25"WG
Box Element Beryllium Copper
-30/+30"WG
-50/+50"WG
0 - 40"WG
0 - 60"WG
0 - 100"WG
0 - 160"WG
Open Stack Beryllium Copper or Stainless Steel
0 - 30"Hg Vac
0 - 250"WG
-15/+15 Psi
0 - 15 Psi
0 - 20 Psi
0 - 25 Psi
0 - 30 Psi
0 - 40 Psi
0 - 60 Psi
0 - 80 Psi
Single Capsule Beryllium Copper or Stainless Steel
3 - 15 Psi Single Capsule Beryllium Copper or Stainless Steel (BS970 316 S16)
0 - 6 Bar
0 - 10 Bar
0 - 16 Bar
0 - 25 Bar
0 - 40 Bar
0 - 60 Bar
0 - 100 Bar
Bourdon Tube Phosphor Bronze or Stainless Steel (BS970 316 S16)
0 - 160 Bar
0 - 250 Bar
0 - 300 Bar
0 - 400 Bar
0 - 600 Bar
0 - 1000 Bar
0 - 1200 Bar
0 - 1600 Bar
Bourdon Tube Stainless Steel (BS970 316 S16)
Calibrations in other units of pressure are available

Tel: (01704) 505333 Fax: (01704) 505334